Specifications
Cooling Method | Air Cooling (forced - fan) |
Supply Voltage | 3Ph 200V 50/60Hz |
COOLPAK 5000 e LV - 2 CP (2x COOLVAC eSL or 2x COOLPOWER e by using 2x COOL.DRIVEi)
Variant
Explore the range of variants given below to compare the product
Short Description | Part Number |
---|---|
840000E5201 | |
840000E5202 | |
840000E5211 | |
840000E5222 | |
840000E5401 |
Cryo Technology
Cryogenic systems are widely used in the vacuum industry for their ability to achieve ultra-low temperatures and create high vacuum conditions. These systems consist of a compressor unit and a cryogenic refrigerator, which work together to generate a cold environment. Cryogenic pumps are also used for vacuum operations, offering high pumping speeds and low ultimate pressures. Cryogenic technology is popular in industries such as semiconductor manufacturing, scientific research, and space exploration
LEYBOLD CRYOGENIC SYSTEMS - Intelligent. Smart. Economical
With regard to the increasing requirements of the market, Leybold fulfils the expectations of customers with its new range of cryogenic systems combining performant components. The cryogenic systems offer a great range of economical products which can be easily combined to meet your application's requirements.
The Leybold cooling systems consist of: COOLPAK e: Compressor unit & COOLPOWER e: Cryogenic refrigerator
The cryogenic pump systems consist of: COOLPAK e: Compressor unit & COOLVAC e: Cryogenic pump
COOLPAK
COOLPAK e compressors are backward compatible and work with either the i-Series as well as with the newest e-series.
COOLPAK CP 5000 i
COOLPAK e compressors are available for single and multiple operation of cold heads from the COOLPOWER e line as well as cryo pumps from the COOLVAC e line.
CH-models: These variants are recommended for applications with 1 or 2 cold heads. CH-models cannot operate a COOL.DRIVE.
CP-models: These variants are well suited for applications with COOLVAC eSL pumps. Variants for the operation of one or two pumps are available. COOLVAC eBL pumps or COOLPOWER e products can also be operated with CP-models and in case even be controlled by the COOL.DRIVE. We strongly recommend buying the CP-model as it is more flexible.
The COOLPAK e series uses oil lubricated scroll technology with a frequency converter and variable motor speed to offer excellence in system performance, energy demand and work space environment.
The COOLPAK e helium compressors have a high energy saving potential. The power consumption changes during processing often allowing energy savings of up to 25%. Typical applications have a fluctuating cooling power demand. Today’s compressor units consume widely constant power nearly independent of power demand.
COOLPAK 5000 e LV - 2 CP (2x COOLVAC eSL or 2x COOLPOWER e by using 2x COOL.DRIVEi)
Is the low volts variant of the COOLPAK 5000 i compressor family. It can operate and control up to two cryogenic pumps of type COOLVAC iSL or up to two COOLPOWER i cold heads by using an additional COOL.DRIVE i. It can also operate up to two COOLPOWER i cold heads or COOLVAC iBL pumps.
Features and Benefits
- Innovation and intelligence: Oil lubricated scroll technology and a variable speed drive offer excellence in system performance, energy demand, and workspace environment.
- Innovative scroll technology: Highly efficient hermetical scroll compressor; Motor speed control
- Improved workspace: Very efficient oil retention system; Compact design-Small footprint; "Plug and play" system set up
- Energy saving options & Cost of Ownership: Energy savings due to variable motor speed of compressor and cold head; Up to 25% power input saving by using the ECO mode
- Easy to use: The "plug & play" system design supports the quickest installation and start-up without complicated programming; Easy serviceability (adsorber exchange); Maintenance interval of up to 22,000 h (30,000 h)
General Product Information
Cooling Method | Air Cooling (forced - fan) |
Dimension Height | 0.566 |
Dimension Length | 0.666 |
Dimension Width | 0.446 |
IP Rating | IP40 |
Supply Frequency |
50 Hz
60 Hz |
Power Supply Phase | 3-Ph |
Supply Voltage | 3Ph 200V 50/60Hz |
Weight | 130.00 |
Dimension Comments | The dimensions length, width and height try to describe the outer shape of this particular product in its typical orientation when standing on the ground. We always recommend checking the detailed dimensions given in 2D drawings in the instruction manual or the 3D shapes given in 3D models. |
Connection Inlet / Outlet Flange | | |
connectionHeliumSupply |
Aeroquip 1/2" male (Aeroquip series 5400-8b)
Aeroquip 1/2" male (Aeroquip series 5400-8b) |
Helium Filling Pressure | 1.600 × 10⁶ |
Performance Data
Power Total Rated @50Hz | 8000.00 |
Power Total Rated @60Hz | 8700.00 |
Environmental Conditions
Temperature Ambient Operation Max | 45.00 |
Temperature Ambient Storage Max | 65.00 |
Temperature Ambient Operation Min | 4.00 |
Temperature Ambient Storage Min | -20.00 |
Classification
Dry or Wet Pump | Dry |
High / Medium / Rough Vacuum Classification | High Vacuum Pump |
Vacuum Pump Technology | Cryogenic Helium Compressor |
- 301255656_002_Instructions.pdf - English - Instructions
- 301255661_002_Instructions.pdf - English - Instructions
- 300929413_002_Instructions.pdf - English - Instructions
- 301171504_002_Instructions.pdf - English - Instructions
- 301143214_002_Instructions.pdf - English - Instructions
- 301217240_002_Instructions.pdf - English - Instructions
- cryogenic-systems-3610-0112-02.pdf - English - Sales Material
- 3610 0111 02_cryogenic-systems.pdf - English - Sales Material
- 3610-0400-02-cryogenic-systems-l-shape.pdf - English - Sales Material
- 3610-0400-02-cryogenic-systems-l-shape.pdf - English - Sales Material
- 3610-0112-02-Cryogenic-Systems.pdf - English - Sales Material
- 301255656_003_Instructions.pdf - French - Instructions
- 301255661_003_Instructions.pdf - French - Instructions
- 300929413_003_Instructions.pdf - French - Instructions
- 301143214_003_Instructions.pdf - French - Instructions
- 301217240_003_Instructions.pdf - French - Instructions
- 301255656_001_Instructions.pdf - German - Instructions
- 301255661_001_Instructions.pdf - German - Instructions
- 300929413_001_Instructions.pdf - German - Instructions
- 301171504_001_Instructions.pdf - German - Instructions
- 301143214_001_Instructions.pdf - German - Instructions
- 301217240_001_Instructions.pdf - German - Instructions
- 301255656_011_Instructions.pdf - Simplified Chinese - Instructions
- 301255661_011_Instructions.pdf - Simplified Chinese - Instructions
- 301171504_011_Instructions.pdf - Simplified Chinese - Instructions