Skip to content Skip to navigation

Specifications

Connection Vacuum Inlet Flange DN 1000 ISO-F
Connection vacuum outlet flange DN 160 ISO-K
Cooling Method Water Cooling
lubricantProductDefault LEYBONOL LVO 500
Supply Voltage 3Ph 400V 50Hz
Power Total Rated 24000.00
Pressure Ultimate 7.000 × 10⁻⁶

DIFFVAC DP 50K 400V 3PH TB

Part Number: 1917050KV01DGN

Variant

Explore the range of variants given below to compare the product

Short Description Part Number
1917050KV01DGN
1917050KV02DGN

Oil Diffusion Pumps

Oil Diffusion pumps produce high vacuum and operate with a fast-moving stream of pump fluid in vapor form (oil vapor). All fluid-entrainment pumps have a similar pumping mechanism where the pump fluid is heated by the electrical heater vessel and the oil vapor expands after passing through the jet stack nozzles. The pumped gas molecules diffuse into the vapor stream and exit out of the pumping chamber.

DIFFVAC DP

Leybold’s range of oil diffusion pumps produce high vacuum and operate with a fast-moving stream of pump fluid in vapor form (oil vapor). The DIFFVAC DP series represents the most updated diffusion pump generation. The new advanced design of these vacuum pumps is made for higher energy efficiency, robustness and up-time. Additionally with the combination of excellent pumping speed and high throughput, the DP series keeps customer value in mind. They achieve their highest pumping speeds in pressure ranges from 10-2 to 10-7 mbar.

DP 50K

DIFFVAC DP 50K is available in 400V ~ 3Ph. 50 Hz and 460V ~ 3Ph. 60 Hz. These pumps are accessory-ready variants

 

Features and Benefits

  • The overall features like high pumping speed and high vacuum, high gas throughput of our oil diffusion pumps and reduced oil backstreaming make them a dependable solution for several applications. They are employed in high-vacuum technology to evacuate vacuum chambers. The pumps also have energy efficiency options like Energy Efficiency Controller (EEC) to reduce your carbon footprint. The DP series oil diffusion pumps are also low maintenance due to no wear caused by revolving parts. The pump also focuses on safety with the default monitoring of oil and heater temperature. The thermostat sensor in heating inserts switches it off as soon as the temperature exceeds the pre-set- this protects your pump and the overall process.

General Product Information

Connection vacuum outlet flange DN 160 ISO-K
Connection Vacuum Inlet Flange DN 1000 ISO-F
Cooling Method Water Cooling
Dimension Height 1880.00
Dimension Outer Diameter 1120.00
Dimension Width 1275.00
IP Rating IP20
Supply Frequency 50 Hz
Power Supply Phase 3-Ph
Supply Voltage 3Ph 400V 50Hz
Weight 600.00
Dimension Comments The dimensions length, width and height try to describe the outer shape of this particular product in its typical orientation when standing on the ground. We always recommend checking the detailed dimensions given in 2D drawings in the instruction manual or the 3D shapes given in 3D models.
Connection Inlet / Outlet Flange DN 1000 ISO-F | DN 160 ISO-K
ProductCertification CE

Lubricants

lubricantProductDefault LEYBONOL LVO 500

Performance Data

Power Total Rated 24000.00
Power Total Rated @60Hz 24000.00
Pressure Ultimate 7.000 × 10⁻⁶
Pumping Speed Hydrogen 13.89
Warm Up Time 1800.00

Operation Conditions - Limitations

Pressure Absolute Inlet Continous Max 50.00
Temperature Cooling Water Max 20.00
Temperature Cooling Water Min 15.00

Environmental Conditions

Temperature Ambient Operation Max 0.000
Temperature Ambient Storage Max 70.00
Temperature Ambient Operation Min -55.00
Temperature Ambient Storage Min -20.00

Classification

Dry or Wet Pump Wet
Product Pressure Range High Vacuum: 1·10⁻³ - 1·10⁻⁷ mbar
High / Medium / Rough Vacuum Classification High Vacuum Pump
Region Global Product
Vacuum Pump Technology Diffusion Pump

Material of Construction

Material of Construction Structural steel, Alumininum, copper
Product Title Part Number Price Add to cart