Skip to content Skip to navigation

Specifications

Connection Vacuum Inlet Flange DN 400 ISO-F
Connection vacuum outlet flange DN 160 ISO-K
Cooling Method Water Cooling
lubricantProductDefault LEYBONOL LVO 540
Supply Voltage 3Ph 400V 50Hz
Power Total Rated 8000.00
Pressure Ultimate 6.600 × 10⁻⁴

DIFFVAC OB 400 400V 3PH TB

Part Number: 1918006KV01DGN

Variant

Explore the range of variants given below to compare the product

Short Description Part Number
1918006KV01DGN
1918006KV02DGN

Oil Diffusion Pumps

Oil Diffusion pumps produce high vacuum and operate with a fast-moving stream of pump fluid in vapor form (oil vapor). All fluid-entrainment pumps have a similar pumping mechanism where the pump fluid is heated by the electrical heater vessel and the oil vapor expands after passing through the jet stack nozzles. The pumped gas molecules diffuse into the vapor stream and exit out of the pumping chamber.

DIFFVAC OB

Leybold’s DIFFVAC OB series booster pumps are a new level of productivity and robustness for the industrial market. Ideal for even the harshest applications, the DIFFVAC OB series ensure easy maintenance and high vacuum performance too. As oil vapor booster pumps, they are always operated in conjunction with forevacuum pumps. They are water-cooled and built on the oil diffusion principle and are used to evacuate vacuum chambers.

The DIFFVAC OB series of oil vapor boosters are ideally suited for processes where you need pumping speed and gas-throughputs, which could not be covered by mechanical booster pumps.

OB 400

DIFFVAC OB 400 is available in 400V ~ 3Ph. 50 Hz and 460V ~ 3Ph. 60 Hz. These pumps are accessory-ready variants

 

Features and Benefits

  • The features of OB series allow direct heating concept ensures a fast heat-up time and the large oil volume a long standby time. Even dust and dirt have no influence on the OB series’ vacuum performance. The sludge tank draining also enables removal of collected dust for cleaner operations and easier maintenance. The pumps also have energy efficiency options like Energy Efficiency Controller (EEC) to reduce your carbon footprint. The pump also focuses on safety with the default monitoring of oil and heater temperature. The thermostat sensor in heating inserts switches it off as soon as the temperature exceeds the pre-set- this protects your pump and the overall process.

General Product Information

Connection vacuum outlet flange DN 160 ISO-K
Connection Vacuum Inlet Flange DN 400 ISO-F
Cooling Method Water Cooling
Dimension Height 2.41
Dimension Outer Diameter 1.09
Dimension Width 1.25
IP Rating IP20
Supply Frequency 50 Hz
Power Supply Phase 3-Ph
Supply Voltage 3Ph 400V 50Hz
Weight 550.00
Dimension Comments The dimensions length, width and height try to describe the outer shape of this particular product in its typical orientation when standing on the ground. We always recommend checking the detailed dimensions given in 2D drawings in the instruction manual or the 3D shapes given in 3D models.
Connection Inlet / Outlet Flange DN 400 ISO-F | DN 160 ISO-K
certificationMotor CE

Lubricants

lubricantProductDefault LEYBONOL LVO 540

Performance Data

Power Total Rated 8000.00
Power Total Rated @50Hz 8000.00
Pressure Ultimate 6.600 × 10⁻⁴
Warm Up Time 3000.00

Operation Conditions - Limitations

Oil Capacity Max 0.025
Pressure Absolute Inlet Continous Max 200.00
Temperature Cooling Water Max 30.00
Temperature Cooling Water Min 15.00

Classification

Dry or Wet Pump Wet
Product Pressure Range High Vacuum: 1·10⁻³ - 1·10⁻⁷ mbar
High / Medium / Rough Vacuum Classification High Vacuum Pump
Region Global Product
Vacuum Pump Technology Diffusion Pump

Material of Construction

Material of Construction Structural steel, copper, Mineral wool/glassfibre mixture
Product Title Part Number Price Add to cart
Angle Valve - BAV DN 400 ISO-K/F 504139V003 -