Specifications
Connection Vacuum Inlet Flange | DN 400 ISO-F |
Connection vacuum outlet flange | DN 160 ISO-K |
Cooling Method | Water Cooling |
lubricantProductDefault | LEYBONOL LVO 540 |
Supply Voltage | 3Ph 400V 50Hz |
Power Total Rated | 8000.00 |
Pressure Ultimate | 6.600 × 10⁻⁴ |
DIFFVAC OB 400 400V 3PH TB
Variant
Explore the range of variants given below to compare the product
Short Description | Part Number |
---|---|
1918006KV01DGN | |
1918006KV02DGN |
Oil Diffusion Pumps
Oil Diffusion pumps produce high vacuum and operate with a fast-moving stream of pump fluid in vapor form (oil vapor). All fluid-entrainment pumps have a similar pumping mechanism where the pump fluid is heated by the electrical heater vessel and the oil vapor expands after passing through the jet stack nozzles. The pumped gas molecules diffuse into the vapor stream and exit out of the pumping chamber.
DIFFVAC OB
Leybold’s DIFFVAC OB series booster pumps are a new level of productivity and robustness for the industrial market. Ideal for even the harshest applications, the DIFFVAC OB series ensure easy maintenance and high vacuum performance too. As oil vapor booster pumps, they are always operated in conjunction with forevacuum pumps. They are water-cooled and built on the oil diffusion principle and are used to evacuate vacuum chambers.
The DIFFVAC OB series of oil vapor boosters are ideally suited for processes where you need pumping speed and gas-throughputs, which could not be covered by mechanical booster pumps.
OB 400
DIFFVAC OB 400 is available in 400V ~ 3Ph. 50 Hz and 460V ~ 3Ph. 60 Hz. These pumps are accessory-ready variants
Features and Benefits
- The features of OB series allow direct heating concept ensures a fast heat-up time and the large oil volume a long standby time. Even dust and dirt have no influence on the OB series’ vacuum performance. The sludge tank draining also enables removal of collected dust for cleaner operations and easier maintenance. The pumps also have energy efficiency options like Energy Efficiency Controller (EEC) to reduce your carbon footprint. The pump also focuses on safety with the default monitoring of oil and heater temperature. The thermostat sensor in heating inserts switches it off as soon as the temperature exceeds the pre-set- this protects your pump and the overall process.
General Product Information
Connection vacuum outlet flange | DN 160 ISO-K |
Connection Vacuum Inlet Flange | DN 400 ISO-F |
Cooling Method | Water Cooling |
Dimension Height | 2.41 |
Dimension Outer Diameter | 1.09 |
Dimension Width | 1.25 |
IP Rating | IP20 |
Supply Frequency | 50 Hz |
Power Supply Phase | 3-Ph |
Supply Voltage | 3Ph 400V 50Hz |
Weight | 550.00 |
Dimension Comments | The dimensions length, width and height try to describe the outer shape of this particular product in its typical orientation when standing on the ground. We always recommend checking the detailed dimensions given in 2D drawings in the instruction manual or the 3D shapes given in 3D models. |
Connection Inlet / Outlet Flange | DN 400 ISO-F | DN 160 ISO-K |
certificationMotor | CE |
Lubricants
lubricantProductDefault | LEYBONOL LVO 540 |
Performance Data
Power Total Rated | 8000.00 |
Power Total Rated @50Hz | 8000.00 |
Pressure Ultimate | 6.600 × 10⁻⁴ |
Warm Up Time | 3000.00 |
Operation Conditions - Limitations
Oil Capacity Max | 0.025 |
Pressure Absolute Inlet Continous Max | 200.00 |
Temperature Cooling Water Max | 30.00 |
Temperature Cooling Water Min | 15.00 |
Classification
Dry or Wet Pump | Wet |
Product Pressure Range | High Vacuum: 1·10⁻³ - 1·10⁻⁷ mbar |
High / Medium / Rough Vacuum Classification | High Vacuum Pump |
Region | Global Product |
Vacuum Pump Technology | Diffusion Pump |
Material of Construction
Material of Construction | Structural steel, copper, Mineral wool/glassfibre mixture |
- 301246280_035_Instructions.pdf - Brazilian Portuguese - Instructions
- 301246280_002_Instructions.pdf - English - Instructions
- OnePager_DIFFVAC_OB_web.pdf - English - Sales Material
- 301246280_003_Instructions.pdf - French - Instructions
- 301246280_001_Instructions.pdf - German - Instructions
- 301246280_004_Instructions.pdf - Italian - Instructions
- 301246280_012_Instructions.pdf - Japanese - Instructions
- 301246280_014_Instructions.pdf - Korean - Instructions
- 301246280_011_Instructions.pdf - Simplified Chinese - Instructions
- 301246280_006_Instructions.pdf - Spanish (European) - Instructions
- 301246280_026_Instructions.pdf - Traditional Chinese - Instructions
Product Title | Part Number | Price | Add to cart |
---|---|---|---|
Angle Valve - BAV DN 400 ISO-K/F | 504139V003 | - |